Service Manual
Series T90 Axial Piston Pumps
Minor repair
Adding an Auxiliary pad to a pump previously without one
Orienting the alignment pin
(outside look ing into pump)
J95
50 |
©
Danfoss | March 2020
1. Remove the six retaining screws (H80) and remove the retaining plate (H70) and cover plate (J15).
Remove the cover plate
H40
H70
H80
2. Observe the alignment pin (H40). If the pin remains in the charge pump, leave it in place. If the pin
comes out with the cover plate, reinstall it in the geroter eccentric.
Ensure that a cover for left hand rotation is used. (See instructions included with the auxiliary pad kit).
Gerotor
assembly
Alignment pin
Left hand rotation
J60
J80
J92
P108928
H80
J90
J10
J15
J30
H70
J50
AX216086485386en-000101