Displacement Limiter Adjustment - Danfoss T90 Series Service Manual

Axial piston pumps
Table of Contents

Advertisement

Service Manual
Series T90 Axial Piston Pumps
Adjustments

Displacement limiter adjustment

©
Danfoss | March 2020
Multi-Function Valve with Bypass Function Engaged
Opening bypass valve
allows flow to circuit
Bypass
through multi-function valves
actuator
Bypass actuator torque
Frame size
055 – 100
You can limit the maximum displacement in either direction.
1. Loosen the lock nut (F212) while holding the adjusting screw (F213) steady.
2. Rotate the adjusting screw some amount (using information in the following table). Rotating the
adjusting screw clockwise decreases the maximum displacement of the pump while rotating the
adjusting screw counterclockwise increases the maximum displacement.
C
Caution
Take care in adjusting displacement limiters to avoid undesirable flow or speed conditions. Re-torque
lock nut (F212) after every adjustment to prevent an unexpected change in operating conditions and
to prevent external leakage during unit operation.
3. One turn of the adjusting screw changes the maximum displacement as shown in table below
4. After establishing the desired maximum displacement setting, torque the lock nut to the torque
shown in table below.
Displacement limiter adjustment
P104 144E
Torque
41 N•m [30 lbf•ft]
F213
I
Adjusting screw
F212
Lock nut
Lock nut torque
P106 164E
AX216086485386en-000101 | 33

Advertisement

Table of Contents
loading

Table of Contents