Adding An Auxiliary Pad To A Pump Previously Without One - Danfoss 90 Series Service Manual

Hide thumbs Also See for 90 Series:
Table of Contents

Advertisement

Service Manual
Minor repair

Adding an Auxiliary pad to a pump previously without one

Orienting the alignment pin
(outside looking into pump)
J95
50
Series 90 Pumps
1. Remove the six retaining screws (H80) and remove the retaining plate (H70) and cover plate (J15).
Remove the cover plate
H40
H70
H80
2. Observe the alignment pin (H40). If the pin remains in the charge pump, leave it in place. If the pin
comes out with the cover plate, reinstall it in the geroter eccentric.
Ensure that a cover for left hand rotation is used. (See instructions included with the auxiliary pad kit).
Gerotor
assembly
Alignment pin
Left hand rotation
J60
J80
J92
520L0818 • Rev 0101 • August 2015
P108928
H80
J90
J10
J15
J30
H70
J50
P108929