Adey MagnaClean CMX MIDI PRO ASSIST Installation And Servicing page 15

Sidestream monitored filtration
Table of Contents

Advertisement

PARAMETER PROGRAMMING MODE - DATA LOGGING MENU (Code: 111)
Parameter
#
Last Service Date Automatically updates when a new service date
DL1
Service Date
DL2
DL3 Pump Hours
Current water
DL4
flow I/min
Water Volume in
DL5
last 24 hours
Water volume
since last
Pressure
DL6
Difference Alarm
activation
Total Water
DL7
Volume
Description
has been entered and will be visible next time the
user accesses parameters
Automatically updates when a new service date
has been entered
Total pump operation time (Auto-Update)
Flow rate through sensor at that point in time
Amount of water that has passed through the filter
during the previous 24 hours
Flow rate through sensor at that point in time
Total amount of water that has passed through the
filter since the unit was last powered ON
Default
Range
-
-
-
-
0 - 999
1 = 24 hrs
Auto-
Update
Auto-
Update
Auto-
Update
Auto-
Update
15

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MagnaClean CMX MIDI PRO ASSIST and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Magnaclean cmx midi proFl1-03-06632Fl1-03-06631

Table of Contents