*NOTE: PARAMETER 1:
- If Parameter 1 "Cartridge Present" is set to "YES", Parameters 2 & 3 are not activated.
- If Parameter 1 "Cartridge Present" is set to "NO", Parameters 2 & 3 are activated and the timer
will be active from that point.
**NOTE: PARAMETER 2:
- Parameter 2 "Magnet Only Service Warning" setting, (Daily, Weekly or Monthly) will affect the
default value of Parameter 3 "Magnet Only Service Warning Duration", e.g. with Parameter 2 set
at the default "Daily" setting, the controller will provide a warning alarm every 2 days by default.
If Parameter 2 is changed to "Weekly" the controller will provide a warning alarm every 2 weeks.
Default Parameter 3 values can be manually changed during Parameter Programming Mode
within a range of 1 – 12 days, weeks or months as applicable.
PARAMETER PROGRAMMING MODE - CUSTOMER DATA MENU (Code: 815)
PRESS & HOLD 'SET' & 'UP' TO PASS TO PARAMETER MENUS
Parameter
#
Cartridge Present Monitors presence of a filter cartridge
P1
ID Number
P4
Battery Activation Enable or disable the battery, (maintains date &
P5
Last Service Date Automatically updates when a new service date
DL1
Service Date
DL2
Pump Hours
DL3
Current water
DL4
flow I/min
Water Volume in
DL5
last 24 hours
Water volume
since last
Pressure
DL6
Difference Alarm
activation
Total Water
DL7
Volume
14
Description
Address for ModBus
time settings if power lost to the controller - on
first power up, battery will automatically activate
has been entered and will be visible next time the
user accesses parameters
Automatically updates when a new service date
has been entered
Total pump operation time (Auto-Update)
Flow rate through sensor at that point in time
Amount of water that has passed through the filter
during the previous 24 hours
Flow rate through sensor at that point in time
Total amount of water that has passed through the
filter since the unit was last powered ON
Default
Range
No
Yes/No
0
0 - 99
No
Yes/No
-
-
Auto-
Update
Auto-
Update
Auto-
Update
Auto-
Update
Auto-
Update
Auto-
Update
Need help?
Do you have a question about the MagnaClean CMX MIDI PRO ASSIST and is the answer not in the manual?