Main Functions

1.11 Inverter POWERFUL Operation

Outline
In order to maximize the benefits of the cooling and heating capacity, operate the air conditioner by
increasing the indoor fan rotating speed and the compressor frequency.
Detail
When POWERFUL button is pressed, the fan speed and target temperature are converted to the
following states for 20 minutes.
Operation mode
COOL
DRY
HEAT
FAN
AUTO
Ex.) : POWERFUL operation in cooling mode.
Target temp.
18˚C (64˚F)
POWERFUL ON
POWERFUL OFF
39
H tap + 90 rpm
Dry rotating speed +
H tap + 90 rpm
H tap + 90 rpm
Same as cooling /
heating in POWERFUL
It should be the lower limit of cooling temperature.
Fan
90 rpm
H tap
Set tap
Fan speed
Target temperature
18°C (64°F)
Lowered by 2°C (3.6°F)
50 rpm
30°C (86°F)
The target temperature is
kept unchanged.
operation
20 minutes
SiUS12-928_A
It counts 20 min. also in the remote controller.
Ending condition: "or" in 1 to 3
1. After the lapse of 20 minutes.
2. Operation OFF
3. POWERFUL operation is OFF.