SiUS12-928_A
5.19 Position Sensor Abnormality
H6
Remote
Controller
Display
Outdoor Unit LED
A
5
Display
Method of
A compressor startup failure is detected by checking the compressor running condition through the
position detection circuit.
Malfunction
Detection
If the error repeats 8 times, the system is shut down.
Malfunction
Reset condition: Continuous run for about 5 minutes without any other error
Decision
Conditions
Disconnection of the compressor relay cable
Supposed
Defective compressor
Causes
Defective outdoor unit PCB
Startup failure caused by the closed stop valve
Input voltage out of specification
Service Diagnosis
1
4
2
4
3
1
4
1
Troubleshooting
128