Night Quiet Mode - Daikin SUPER MULTI NX G Series Service Manual

Table of Contents

Advertisement

SiUS12-928_A
3.3

NIGHT QUIET Mode

If NIGHT QUIET mode is to be used, initial settings must be made when the unit is installed.
Explain the function of NIGHT QUIET mode, as described below, to the customer, and confirm
whether or not the customer wants to use NIGHT QUIET mode.
NIGHT QUIET mode function reduces operating noise of the outdoor unit at nighttime. This function
is useful if the customer is worried about the effects of the operating noise on the neighbors.
However, if NIGHT QUIET mode is running, cooling capacity is reduced.
 Procedure
1. Remove the SW5 jumper switch on the service monitor PCB of the outdoor unit.
2. Install the removed jumper switch as described below. This jumper switch is needed later to
Trial Operation and Field Settings
Once the settings are complete, reset the power.
disable this setting.
Service monitor PCB

NIGHT QUIET mode

setting switch (SW5)
(R10814)
Jumper switch
After removing
Field Settings
(R10813)
222