10 Configuration
10.1
About standby electricity saving
function
INFORMATION
This function is available only for the indoor units listed
below.
The standby electricity saving function:
▪ turns OFF the power supply to the outdoor unit and,
▪ turns ON the standby electricity saving mode on the indoor unit.
The standby electricity saving function works with following units:
FTXM, FTXJ, FVXM, FTXA, CTXA, CTXM, CVXM, EKHWET
If another indoor unit is used, the connector for standby electric
saving MUST be plugged in.
The standby electricity saving function is turned OFF before
shipping.
10.1.1
To turn ON standby electricity saving
function
Prerequisite: The main power supply MUST be turned OFF.
1 Remove the service cover.
2 Disconnect the selective standby electricity saving connector.
3 Turn ON the main power supply.
10.2

About priority room function

INFORMATION
▪ The priority room function requires initial settings to be
made during the installation of the unit. Ask the
customer in which rooms he plans to use this function
and make the necessary settings during installation.
▪ The priority room setting is only applicable for an air
conditioner indoor unit and only one room can be set.
The indoor unit for which the priority room setting is applied takes
priority in the following cases:
▪ Operation mode priority: If the priority room function is set on an
indoor unit, all other indoor units enter the standby mode.
▪ Priority during high-power operation: If the indoor unit on which
the priority room function is set operates at high power, the other
indoor units will run with reduced capabilities.
▪ Quiet operation priority: If the indoor unit on which the priority
room function is set to quiet operation, the outdoor unit will also
run quietly.
Ask the customer in which rooms he plans to use this function and
make the necessary settings during installation. Setting it in the
guest rooms is convenient.
Installation manual
14
10.2.1

To set the priority room function

1 Remove the switch cover on the service PCB.
2 Set the switch (SW4) for the indoor unit for which you want to
activate the priority room function to ON.
3 Reset the power.
10.3

About night quiet mode

The night quiet mode function makes the outdoor unit run more
quietly at nighttime. This will reduce the cooling capacity of the unit.
Explain Night quiet mode to the customer and confirm if customer
wants to use this mode.
10.3.1

To turn ON the night quiet mode

1 Remove the switch cover on the service PCB.
2 Set the night quiet mode switch (SW6-1) to ON.
10.4

About heat mode lock

Heat mode lock limits the unit to heat operation.
10.4.1

To turn ON heat mode lock

1 Remove the switch cover on the service PCB.
2 Set the heat mode lock switch (SW5-1) to ON.
ON
OFF
E
D
C
B
A
E
D
A
2
C
B
A
1
SW4
2
3
4
5
ON
OFF
2
A
1
1
2
2
1
2
SW6
3
4
5
4MWXM-A9