HP StorageWorks Modular Smart Array 1500 cs Installation Manual page 31

Hide thumbs Also See for StorageWorks Modular Smart Array 1500 cs:
Table of Contents

Advertisement

2. If the holes in the rack uprights are round instead of square, remove the
3. Install the rails in the rack:
Note:
into the rack uprights.
Figure 4: Installing the front of the right rail into the rack
Modular Smart Array 1500 cs Installation Guide
c. Use a pencil to mark the required location of the scissor-like locking
latches on the rails, as indicated by the template.
d. Repeat these steps to mark the back of the rack, using the information on
the back of the template as a guide.
standard pins from the rails and replace them with the round-hold pins
provided with the rail kit.
The pins in the rails are load-bearing. Do not remove the
WARNING:
standard pins except to replace them with the pins for round-hole racks.
a. Identify the left (L) and right (R) rack rails by markings stamped into the
rails.
b. Insert the front end of the right rack rail into the inside front of the rack
until the pins extend through the holes marked during the rack template
procedure.
Be sure that the scissor-type locking latch engages when the end of the rail seats
Installation Procedures - All Deployments
31