11-6. Overload Protection

2
1
3
OM-283762 Page 58
.
A complete Parts List is available at www.MillerWelds.com
!
Stop engine.
.
When a circuit breaker, supple-
mentary protector or fuse
opens, it usually indicates a
more serious problem exists.
Contact a Factory Authorized
Service Agent.
1
Supplementary Protector CB1
CB1 is located on the front panel
and protects the auxiliary power re-
ceptacles and weld/battery charge
module from overload. If CB1
opens, none of the AC receptacles
or weld/battery charge functions
will work. Place switch in On posi-
tion to reset.
2
Supplementary Protector CB2
CB2 is located on the front panel
and protects 120V receptacle RC2
from overload. If CB2 opens, RC2
will not work. Press button to reset.
3
Supplementary Protector CB3
CB3 is located on the front panel
and protects 120V receptacle RC3
from overload. If CB3 opens, RC3
will not work. Press button to reset.
4
Fuse/Relay Module Label
Engine and control fuses are locat-
ed in the fuse/relay module located
in the compressor compartment.
Fuses protect engine and control
components.
4