10-3. Connecting Weld Output Cables

1
Tools Needed:
3/4 in. (19 mm)
!
Turn off power before connecting to
weld output terminals.
!
Failure to properly connect weld
cables may cause excessive heat
and start a fire, or damage your ma-
chine.
.
Do not place anything between weld
Notes
.
A complete Parts List is available at www.MillerWelds.com
6
3
4
5
cable terminal and copper bar. Make
sure that the surfaces of the weld cable
terminal and copper bar are clean.
1
Correct Weld Cable Connection
2
Incorrect weld Cable Connection
3
Weld Output Terminal
4
Supplied Weld Output Terminal Nut
2
5
Weld Cable Terminal
6
Copper Bar
Remove supplied nut from weld output ter-
minal. Slide weld cable terminal onto weld
output terminal and secure with nut so that
weld cable terminal is tight against copper
bar.
connecting weld output cables 3−2010