5. PARAMETERS
No.
Symbol
PSD27
**SDID1
Input device - Fixing-diagnosis execution selection 1 at start-up
Select whether execute a fixing-diagnosis of DI1_ to DI4_ or not at start-up.
Setting
digit
_ _ _ x
_ _ x _
_ x _ _
x _ _ _
PSD28
**SDID1
Input device - Fixing-diagnosis execution selection 2 at start-up
Select whether execute a fixing-diagnosis of DI5_/DI6_ or not at start-up.
Setting
digit
_ _ _ x
_ _ x _
_ x _ _
x _ _ _
Name and function
Explanation
Fixing-diagnosis execution selection DI1 at start-up
Select whether execute a fixing-diagnosis of DI1_ or not at start-
up.
0: Not diagnose
1: Diagnose
Fixing-diagnosis execution selection DI2 at start-up
Select whether execute a fixing-diagnosis of DI2_ or not at start-
up.
0: Not diagnose
1: Diagnose
Fixing-diagnosis execution selection DI3 at start-up
Select whether execute a fixing-diagnosis of DI3_ or not at start-
up.
0: Not diagnose
1: Diagnose
Fixing-diagnosis execution selection DI4 at start-up
Select whether execute a fixing-diagnosis of DI4_ or not at start-
up.
0: Not diagnose
1: Diagnose
Explanation
Fixing-diagnosis execution selection DI5 at start-up
Select whether execute a fixing-diagnosis of DI5_ or not at start-
up.
0: Not diagnose
1: Diagnose
Fixing-diagnosis execution selection DI6 at start-up
Select whether execute a fixing-diagnosis of DI6_ or not at start-
up.
0: Not diagnose
1: Diagnose
For manufacturer setting
5 - 19
Initial
Setting
value
range
[unit]
Initial
Setting
value
range
1h
0h
to
1h
1h
0h
to
1h
1h
0h
to
1h
1h
0h
to
1h
Initial
Setting
value
range
1h
0h
to
1h
1h
0h
to
1h
0h
0h