3. SIGNALS AND WIRING

3.7 Wiring method of CN10A/CN10B connectors

Wiring to CN10 and CN10B, use the connector DFMC 1, 5/9-STF-3, 5 (Phoenix Contact) packed with the
amplifier.
(1) Fabrication on cable insulator
Fabricate a wire using its applicable wire size of AWG 24 to 16 and strip the wire end to make the
stripped length 10 mm ± 0.5 mm.
(2) Inserting wire
With pressing the release button with a flat-blade screwdriver with the blade edge width of 2.0 mm to 2.5
mm, insert a wire all the way in. And remove the screwdriver.
It is recommended to use "model: SZS 0,4X2,5, product No.: 1205037" of Phoenix Contact for the flat
head screwdriver.
(3) Removing wire
With pressing the release button with a flat-blade screwdriver, pull out the wire.
Upper row
Lower row
Release button
Wire insertion hole
3 - 16
Flat-blade
Wire
screwdriver
Remove the screwdriver
to connect.