5. PARAMETERS
No.
Symbol
PSD17
**SDIF6
Input device - Noise rejection filtering time DI6
Select a filtering time to reduce noise of DI6A (CN10A-15) and DI6B (CN10B-15).
Setting method is the same as [Pr. PSD12].
Setting
digit
_ _ x x
_ x _ _
x _ _ _
PSD18
**SDIDT1
Mismatch permissible time DI1
Set a threshold of mismatch time of DI1A (CN10A-4) and DI1B (CN10B-4). When a
mismatch of DI1A and DI1B continues over the setting value, [AL. 79.7 Mismatched input
signal error] will occur. Setting "0" will disable alarm detections.
PSD19
**SDIDT2
Mismatch permissible time DI2
Set a threshold of mismatch time of DI2A (CN10A-13) and DI2B (CN10B-13). When a
mismatch of DI2A and DI2B continues over the setting value, [AL. 79.7 Mismatched input
signal error] will occur. Setting "0" will disable alarm detections.
PSD20
**SDIDT3
Mismatch permissible time DI3
Set a threshold of mismatch time of DI3A (CN10A-5) and DI3B (CN10B-5). When a
mismatch of DI3A and DI3B continues over the setting value, [AL. 79.7 Mismatched input
signal error] will occur. Setting "0" will disable alarm detections.
PSD21
**SDIDT4
Mismatch permissible time DI4
Set a threshold of mismatch time of DI4A (CN10A-14) and DI4B (CN10B-14). When a
mismatch of DI4A and DI4B continues over the setting value, [AL. 79.7 Mismatched input
signal error] will occur. Setting "0" will disable alarm detections.
PSD22
**SDIDT5
Mismatch permissible time DI5
Set a threshold of mismatch time of DI5A (CN10A-6) and DI5B (CN10B-6). When a
mismatch of DI5A and DI5B continues over the setting value, [AL. 79.7 Mismatched input
signal error] will occur. Setting "0" will disable alarm detections.
PSD23
**SDIDT6
Mismatch permissible time DI6
Set a threshold of mismatch time of DI6A (CN10A-15) and DI6B (CN10B-15). When a
mismatch of DI6A and DI6B continues over the setting value, [AL. 79.7 Mismatched input
signal error] will occur. Setting "0" will disable alarm detections.
Name and function
Explanation
Noise rejection filtering time DI6
Refer to table 5.3 for settings.
For manufacturer setting
5 - 17
Initial
Setting
value
range
[unit]
Initial
Setting
value
range
01h
00h
to
05h
0h
0h
20
0
[ms]
to
60000
20
0
[ms]
to
60000
20
0
[ms]
to
60000
20
0
[ms]
to
60000
20
0
[ms]
to
60000
20
0
[ms]
to
60000