Canon imageCLASS X LBP1238 II Service Manual page 180

Hide thumbs Also See for imageCLASS X LBP1238 II:
Table of Contents

Advertisement

COPIER (Service mode for printer) > FUNCTION (Operation / inspection mode) > INSTALL
RGW-PORT
Detail
Use Case
Adj/Set/Operate Method
Caution
Display/Adj/Set Range
Default Value
Related Service Mode
Supplement/Memo
COM-TEST
Detail
Use Case
Adj/Set/Operate Method
Caution
Related Service Mode
Supplement/Memo
COM-RSLT
Detail
Use Case
Adj/Set/Operate Method
Caution
Display/Adj/Set Range
Default Value
Related Service Mode
Supplement/Memo
COM-LOG
Detail
Use Case
Adj/Set/Operate Method
Caution
Display/Adj/Set Range
Related Service Mode
Supplement/Memo
Setting of Remote Monitoring Server port number when using Embedded-RDS
To set the port number of Remote Monitoring Server to be used for Embedded-RDS.
When using Embedded-RDS
1) Enter the setting value, and then press Apply key.
2) Turn OFF/ON the main power switch.
Be sure to use ERDS, RGW-PORT, COM-TEST, COM-RSLT, and COM-LOG as a set.
1 to 65535
443
COPIER > FUNCTION > INSTALL > ERDS, COM-TEST, COM-RSLT, COM-LOG
Embedded-RDS: Function to send device information such as the device counter, failure, and
consumables to the sales company's server via SOAP protocol
Execution of Embedded-RDS communication test
To execute Embedded-RDS communication test.
If the connection fails, the information is added to the communication error log.
When using E-RDS
Select the item, and then press Yes key.
Be sure to use ERDS, RGW-PORT, COM-TEST, COM-RSLT, and COM-LOG as a set.
COPIER > FUNCTION > INSTALL > ERDS, RGW-PORT, COM-RSLT, COM-LOG
Embedded-RDS: Function to send device information such as the device counter, failure, and
consumables to Remote Monitoring Server via SOAP protocol
Display of Embedded-RDS comctn test result
To display the Embedded-RDS communication test result.
When using E-RDS
N/A (Display only)
Be sure to use ERDS, RGW-PORT, COM-TEST, COM-RSLT, and COM-LOG as a set.
When not in execution: Unknown
When connection is completed: OK
When connection is failed: NG
Unknown
COPIER > FUNCTION > INSTALL > ERDS, RGW-PORT, COM-TEST, COM-LOG
Embedded-RDS: Function to send device information such as the device counter, failure, and
consumables to Remote Monitoring Server via SOAP protocol
Display of Embedded-RDS comctn error log
To display the Embedded-RDS communication error log.
The dates, times, and error codes of the latest 5 errors that occurred are displayed.
As for the error detail information, the report can be output by executing ERDS-LOG.
When using Embedded-RDS
N/A (Display only)
Be sure to use ERDS, RGW-PORT, COM-TEST, COM-RSLT, and COM-LOG as a set.
Date: 6 digits
Time: 4 digits
Error code: 8 digits
COPIER > FUNCTION > INSTALL > ERDS, RGW-PORT, COM-TEST, COM-RSLT
COPIER > FUNCTION > MISC-P > ERDS-LOG
Embedded-RDS: Function to send device information such as the device counter, failure, and
consumables to Remote Monitoring Server via SOAP protocol
170
9. Service Mode

Advertisement

Table of Contents
loading

Table of Contents