COPIER (Service mode for printer) > FUNCTION (Operation / inspection mode) > INSTALL
RGW-PORT
Detail
Use Case
Adj/Set/Operate Method
Caution
Display/Adj/Set Range
Default Value
Related Service Mode
Supplement/Memo
COM-TEST
Detail
Use Case
Adj/Set/Operate Method
Caution
Related Service Mode
Supplement/Memo
COM-RSLT
Detail
Use Case
Adj/Set/Operate Method
Caution
Display/Adj/Set Range
Default Value
Related Service Mode
Supplement/Memo
COM-LOG
Detail
Use Case
Adj/Set/Operate Method
Caution
Display/Adj/Set Range
Related Service Mode
Supplement/Memo
Setting of Remote Monitoring Server port number when using Embedded-RDS
To set the port number of Remote Monitoring Server to be used for Embedded-RDS.
When using Embedded-RDS
1) Enter the setting value, and then press Apply key.
2) Turn OFF/ON the main power switch.
Be sure to use ERDS, RGW-PORT, COM-TEST, COM-RSLT, and COM-LOG as a set.
1 to 65535
443
COPIER > FUNCTION > INSTALL > ERDS, COM-TEST, COM-RSLT, COM-LOG
Embedded-RDS: Function to send device information such as the device counter, failure, and
consumables to the sales company's server via SOAP protocol
Execution of Embedded-RDS communication test
To execute Embedded-RDS communication test.
If the connection fails, the information is added to the communication error log.
When using E-RDS
Select the item, and then press Yes key.
Be sure to use ERDS, RGW-PORT, COM-TEST, COM-RSLT, and COM-LOG as a set.
COPIER > FUNCTION > INSTALL > ERDS, RGW-PORT, COM-RSLT, COM-LOG
Embedded-RDS: Function to send device information such as the device counter, failure, and
consumables to Remote Monitoring Server via SOAP protocol
Display of Embedded-RDS comctn test result
To display the Embedded-RDS communication test result.
When using E-RDS
N/A (Display only)
Be sure to use ERDS, RGW-PORT, COM-TEST, COM-RSLT, and COM-LOG as a set.
When not in execution: Unknown
When connection is completed: OK
When connection is failed: NG
Unknown
COPIER > FUNCTION > INSTALL > ERDS, RGW-PORT, COM-TEST, COM-LOG
Embedded-RDS: Function to send device information such as the device counter, failure, and
consumables to Remote Monitoring Server via SOAP protocol
Display of Embedded-RDS comctn error log
To display the Embedded-RDS communication error log.
The dates, times, and error codes of the latest 5 errors that occurred are displayed.
As for the error detail information, the report can be output by executing ERDS-LOG.
When using Embedded-RDS
N/A (Display only)
Be sure to use ERDS, RGW-PORT, COM-TEST, COM-RSLT, and COM-LOG as a set.
Date: 6 digits
Time: 4 digits
Error code: 8 digits
COPIER > FUNCTION > INSTALL > ERDS, RGW-PORT, COM-TEST, COM-RSLT
COPIER > FUNCTION > MISC-P > ERDS-LOG
Embedded-RDS: Function to send device information such as the device counter, failure, and
consumables to Remote Monitoring Server via SOAP protocol
170