2. Hardware

2.1 Specifications

Model
Illumination
Measurement
Range
Resolution
Accuracy
Response Time
Temperature Measurement
Range
Resolution
Accuracy
Relative Humidity Measurement
Range
Resolution
Accuracy
LCD LED Display
LCD Information
Displayed
PWR
Link
PoE
Software
Built-in Web Server
Communication
RS-485 Port
Ethernet Port
Protocol,
Security
Dual Watchdog
System
Real Time Clock
Data Logger
DL-100-E / DL-101-E / DL-110-E / DL-120-E User Manual
DL-100-E
DL-101-E
-
-
-
-
-20 to +60°C (-31 to +176˚F)
0.1°C
Typical: ± 0.4°C; refer to figure 2
0 to 100% RH
0.1% RH
Typical: ±3% RH @ 20 ~ 80% RH;
refer to figure 1
Temperature (°C and °F),
Humidity (RH), Relative,
Humidity, Date and Time
System indicator (Green)
Link/Act indicator (Green)
-
10/100 Base-TX with Auto MDI/MDI-X
Modbus TCP and MQTT
Yes, Module (2.3 seconds), Communication (Programmable)
DL-110-E
0 to 100,000 Lux
PoE indicator (Red)
Yes
Baud Rate = 1200 ~ 115200 bps
DCON, Modbus RTU Modbus TCP
Password and IP Filter
Yes
Yes, 600,000 Records
Version 1.1.3 Dec 2020 - 7 -
DL-120-E
1 Lux
±5%
1 second
-
-
-
-
-
-
-
and MQTT