4.2

Randomized delay

This function is mandatory in the UK and it must be activated and configured.
When the function is enabled, each charging session starts with a random delay
between 0  s and the selected value. The default value is 600 s. The maximum
allowable value is 1800 s. To activate the function follow the steps below:
Select "Country settings" on the homepage
Enable the Randomized delay using the toggle
Use the default value of 600 s as per the UK requirements
This function can also be activated and deactivated by the user in the
Charging
App
DPM PowerMeter
Maximum power
MID counter
Country settings
Operating mode
Wi-Fi settings
1
NOTICE
Once the function is enabled, to make the changes effective, always
restart the wallbox through the dedicated button in the homepage.
eProWallbox
F2ME.EPROXXXXXXXX
0000AB0123456789
2.9.1
2
43
Inst a llat io n M an ual
County settings
Max A 32.00
Max kW 7.40
Load unbalance
OFF
Randomized delay
Maximum delay
600 s