BASIC DATA ASSIGNMENT FOR ISDN
(2) Condition: 24DTR is mounted in Slot 07 of PIM0 and 2DCH is mounted in Slot 05 of
CSCG
130
(for Dch)
The location of DCH (Dch Handler) must be assigned in the "CCH" parameter of this command.
Note 1:
Above is an example when #0 DCH of PA-2DCH circuit card is used.
Note 2:
STEP 6: ACIC1 - With respect to PC assigned in the ADPC command, assign CSCG of the Dch assigned in
STEP 7: ATRK - Assign the trunk data for Dch referring to Figure 3-1 and 3-2.
STEP 8: MBTK - Cancel Make Busy Status of all B channels in the PRT card.
Note:
Circuit card must be initialized after this assignment.
CHAPTER 3
Page 14
Revision 1.0
PIM0, ACSC data is as follows.
CCH
CIC GROUP
00002
0
00002
1
00002
2
00002
3
00002
4
00002
5
00002
6
00002
7
the ACSC command.
CSCG
131
(for Bch)
NDA-24305
CCH
CIC GROUP
00004
0
00004
1
00004
2
00004
3
00004
4
00004
5
00004
6
00004
7