3. Programming
STEP 1: ASYD - System Data 1, Index 16, bits 0-4: Place one - to five-digit station numbers in service.
STEP 2: ASDT - Assign Tenant No., Station No., LEN, and the Telephone Equipment Class (TEC) to the
STEP 3: ANPD - Reserve a number level for station access. Assign for normal and hooking. Assign NND in
STEP 4: ASPA - For a Connection Index as Normal and Hooking, assign the SRV = STN, assign Tenant
station. Also, assign the Service Feature Class and Route Restriction Class.
TN:
Tenant Number
STN: Station Number
LEN: Line Equipment Number (6 digits)
The LEN of the data extension is assigned as TEC 13. The voice LEN is assigned as a
TEC 12. The voice and data LENs are associated as follows:
VOICE
LEN
xx
x
xx
LEN
xx
x
xx
LEN
xx
x
xx
LEN
xx
x
xx
MG
U
GP
TEC: Telephone Class (1-31)
1- DP (10pps)
2 - PB
3 - DP/PB
term
---> 12 - D
---> 13 - Data Terminal via D
14 - Hotline
15 - CAS Line
18 - Virtual Circuit
(For Data Terminals, assign RSCs that allow access to the routes to be used for data
transmission, and the SFC of the data terminal should include SFI 11 = 0, Data Privacy.)
RSC: Route Restriction Class (0-15)
For assignment of RSC, ARSC command.
SFC:
Service Feature Class (0-15)
For Assignment of SFC, ASFC command.
accordance with a predetermined numbering plan. BLF is on.
(TN).
SIMULTANEOUS VOICE AND DATA TRANSMISSION-PRI
DATA
0
LEN
xx
1
LEN
xx
2
LEN
xx
3
LEN
xx
LV
MG
term
NDA-24305
x
xx
4
x
xx
5
x
xx
6
x
xx
7
U
GP
LV
CHAPTER 5
Revision 1.0
Page 145