Q-SIG (CIRCUIT SWITCHED BASIC CALL - ETSI VERSION)
4. Programming
STEP 1: ASYD - Assign the following data.
STEP 2: Assign the numbering plan data for the originating call.
Note 1:
ASPA
LCR (for Enbloc sending)
LCRS (for Overlap sending)
Closed Numbering without office code will not allow in Q-SIG Network.
Note 2:
STEP 3: ARTD - Assign the route data for Bch and Dch at each physical interface.
B-channel route data
CDN
Note 1:
Depending on the level diagram of the network. Data "4" is for standard.
Note that each office must be assigned a different value to avoid collision at the time of call origination.
Note 2:
TRKS=0 (When PRT/DCH is set as "User side" by DIP switch.)
TRKS=1 (When PRT/DCH is set as "Net side" by DIP switch.)
PRT
Dip SW: User side
ARTD:
CHAPTER 6
Page 292
Revision 1.0
SYS-1 Index
186 bit6=1 (ISDN/CCIS is in service)
187=00 Hex
220 bit6=0 (ISDN is in service)
2 (ONSG)
=
2
4 (INSG)
=
2
5 (TF)
=
3
6 (TCL)
=
4
7 (L/T)
=
1
8 (RLP)
=
2
15 (LSG)
= 12
28 (ANS)
=
1
30 (PAD)
=
4
Note 1
31 (OGRL)
=
1
32 (ICRL)
=
1
34 (GUARD) =
1
45 (A/D)
=
1
49 (TRKS)
= 0/1
Note 2
50 (DPLY)
=
1
Note 3
65 (INT)
= 10
66 (DC)
= 15
113 (UUI)
=
1
Note 4
118 (BOB)
=
1
Note 5
Q-SIG
TRKS = 0
D-channel route data
CDN
2 (ONSG)
4 (INSG)
5 (TF)
6 (TCL)
7 (L/T)
15 (LSG)
30 (PAD)
31 (OGRL)
32 (ICRL)
34 (GUARD) =
45 (A/D)
65 (INT)
118 (BOB)
PRT
Dip SW: Net side
ARTD:
TRKS = 1
NDA-24305
=
2
=
2
=
3
=
4
=
1
= 13
=
7
Note 1
=
1
=
1
1
=
1
= 10
=
1
Note 5