CHAPTER 14 TROUBLESHOOTING
PD-ME
Executes density auto correction for text or text/photo
mode (reads the PD-DENS output).
1) Place the PD-DENS output on the cupboard glass as
• Place it so that its printed side faces down.
• Place it so that the whiter (lighter) side of the 15
• Place it with reference to the V marking in the rear left
2) Select <PD-ME> to highlight; then, press the OK key.
• OK is shown to indicate that the execution ended
14-194
Operation
follows:
gradations is toward the vertical size plate.
of the copyboard glass.
PD-DENS output
The scanning lamp turns on and off 13 times to make
scans.
successfully; if NG, perform "If PD-ME/DZ-ME is NG"
on p. 14-27.
COPYRIGHT © 1999 CANON INC. CANON 405/335 REV.0 JAN. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
In practice, place
it so that the printed
side is down.