CHAPTER 10 EXTERNALS/AUXILIARY MECHANISMS
4. Laser Scanner Motor Cooling Fan
•
FM5
1) Open the front cover.
2) Remove the inside cover.
3) Disconnect the connector [1], remove the
wire saddle [2], and remove the screw;
then, detach the laser scanner motor
cooling fan (FM5) together with its cover.
[5]
[3]
[2]
Figure 10-534
Caution:
When mounting the fan, be sure that the
marking (arrow indicating the direction
of air current) and the marking on the fan
will match.
10-28
[4]
[1]
COPYRIGHT © 1999 CANON INC. CANON 405/335 REV.0 JAN. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
•
FM6
1) Open the front cover.
2) Release the feeding assembly lever and
the developing assembly lever.
3) Remove the screw [1], and detach the
drum cartridge [2].
[2]
[1]
Figure 10-535
4) Disconnect the connector [3], and remove
the screw [4]; then, slide out the drum
cartridge stay [5] to the front.
(At this time, take care so that the rear of
the stay will not come into contact with
the developing cylinder.)
[3]
Figure 10-536
[5]
[3]
[4]