Download Print this page

Canon GP335 Service Manual page 336

Hide thumbs Also See for GP335:

Advertisement

CHAPTER 10 EXTERNALS/AUXILIARY MECHANISMS
4. Laser Scanner Motor Cooling Fan
FM5
1) Open the front cover.
2) Remove the inside cover.
3) Disconnect the connector [1], remove the
wire saddle [2], and remove the screw;
then, detach the laser scanner motor
cooling fan (FM5) together with its cover.
[5]
[3]
[2]
Figure 10-534
Caution:
When mounting the fan, be sure that the
marking (arrow indicating the direction
of air current) and the marking on the fan
will match.
10-28
[4]
[1]
COPYRIGHT © 1999 CANON INC. CANON 405/335 REV.0 JAN. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
FM6
1) Open the front cover.
2) Release the feeding assembly lever and
the developing assembly lever.
3) Remove the screw [1], and detach the
drum cartridge [2].
[2]
[1]
Figure 10-535
4) Disconnect the connector [3], and remove
the screw [4]; then, slide out the drum
cartridge stay [5] to the front.
(At this time, take care so that the rear of
the stay will not come into contact with
the developing cylinder.)
[3]
Figure 10-536
[5]
[3]
[4]