Download Print this page

Canon GP335 Service Manual page 477

Hide thumbs Also See for GP335:

Advertisement

4
E004 (The SSR has a short circuit, or the heater relay has an error.)
Cause
Fixing heater
Wiring
SSR
DC controller
PCB
Image processor
PCB
COPYRIGHT © 1999 CANON INC. CANON 405/335 REV.0 JAN. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
Step
Check
1
Clear the error in service mode.
2
Does the fixing heater turn on
immediately after power-on?
3
Does the wiring between the SSR,
relay, and DC controller PCB have
a fault?
4
Is 6-7 and 7-8 of the SSR shorted?
5
Replace the DC controller PCB. Is
the problem corrected?
6
CHAPTER 14 TROUBLESHOOTING
Yes/No
NO
See "The fixing heater
fails to turn on." If E000
or E002 occurs, see its
respective descriptions.
If E004 turns on once
again, go to step 3.
YES
Correct the wiring.
YES
Replace the SSR.
YES
End.
NO
Replace the image
processor PCB.
Action
14-59

Advertisement