Inspecting The Fuel Lines And Connections; Bleeding The Fuel System; Open The Hood; Refer To Opening The Hood; Close And Latch The Hood; Refer To Closing The Hood - Toro Reelmaster 5010-H Operator's Manual

Traction unit
Hide thumbs Also See for Reelmaster 5010-H:
Table of Contents

Advertisement

Figure 89
1. Drain valve (fuel tank)
3.
Open the drain valve and allow the fuel to drain
from the tank.
4.
Use clean fuel to flush out the tank.
5.
Close the drain valve.
Inspecting the Fuel Lines
and Connections
Service Interval: Every 400 hours/Yearly (whichever
comes first)
Inspect the fuel lines for deterioration, damage, or
loose connections.
Replace any deteriorated clamps or hoses.
Note:
Prime the fuel system if you replace any fuel
lines; refer to
Priming the Fuel System (page

Bleeding the Fuel System

1.
Prepare the machine for maintenance; refer to
Preparing for Maintenance (page
2.
Ensure that the fuel tank is at least half full.
3.
Open the hood; refer to
49).
4.
Open the air-bleed screw on the fuel-injection
pump
(Figure
90).
g373900
63).
49).
Opening the Hood (page
1. Fuel-injection pump bleed screw
5.
Turn the key in the ignition switch to the O
position.
The electric fuel pump runs, forcing air out
around the air-bleed screw.
Note:
Leave the key in the O
solid stream of fuel flows out around the screw.
6.
Tighten the screw and turn the ignition key to
O
.
FF
7.
Close and latch the hood; refer to
Hood (page
49).
60
Figure 90
position until a
N
Closing the
g421595
N

Hide quick links: