HIKVISION AX PRO User Manual page 99

Hide thumbs Also See for AX PRO:
Table of Contents

Advertisement

the alarm will be triggered.
Panel Main Power Lost
If the option is enabled, an alarm will be triggered when the control panel main supply is
disconnected.
To compliant the EN 50131-3, the report dealy duration should be 10 s.
Click Save.
Arming Options
This function is for the whole alarm system, to inform the user of the current system status before
arming. If it is enabled, there will be a fault prompt and confirmation process for tag readers,
keypads, keyfobs, and APP. If it is not enabled, there will be no fault detection before arming.
Click Configuration → System → Control Panel Option → Arming Options to enter the page.
You can set the following parameters:
Fault Checklist when Arming
The system will check if the device has the faults in the checklist during the arming process.
Fault Voice Prompts on Arming
The system will make voice prompts when arming.
Fault Voice Prompts on Disarming
The system will make voice prompts when disarming.
Regional Certification
Click Configuration → System → Control Panel Option → Regional Certificate to enter the page.
PD6662 is applicable to the UK market. If this function is enabled, the arming function and alarm
logic of the control panel will change.
PD6662
Enable PD6662 standard. Functions that do not meet the standard will not take effect.
Communication Fault Sending Delay
Figure 5-26. Arming Options
98