-Alarm on Zone Activated: If the zone is triggered for the set time, it will alarm.
-Retry Time Period: Set the timeout period.
7. Enable other parameters according to your actual needs.
Note
The supported functions vary depending on the zone types. Refer to the actual zone to set the
function.
Arm Mode
If the zone is a public zone (the zone is belongs to more than one areas), you can set arm
mode.
And: When all linked areas are armed, the zone will arm. When any of linked areas is
disarmed, the zone will disarm.
Or: When any of the linked areas is armed, the zone will arm. When all linked areas are
disarmed, the zone will disarm. When the zone is in alarm, the disarmed areas linked with the
zone cannot be armed.
Stay Arm Bypass
The zone will be automatically bypassed in stay arming.
Cross Zone
PD6662 is not enabled: You need to set the combined time interval.
When the first zone is triggered, the system will start timing after the zone is restored. If the
second zone is triggered within the set time, both zones will give alarms. Otherwise, no alarm
will be triggered.
If the first zone is not be restored, both zones will give alarms when the second zone is
triggered, regardless of whether the set time has elapsed.
PD6662 is enabled: You need to set the combined time interval.
The first zone will give an alarm when triggered. If the first zone is not restored and the
second zone is triggered, the system will report the alarm confirmation.
If the first zone is restored, the system will start timing. If the second zone is triggered within
the set time, the system will report the alarm confirmation.
If the first zone is restored, the system will start timing. If the second zone is not triggered
within the set time, no information will be reported.
Forbid Bypass on Arming
After enabled, you cannot bypass zones when arming.
Chime
Enable the doorbell. Usually used for door magnetic detectors.
Silent Alarm
After enabled, when an alarm is triggered, only the report will be uploaded and no sound is
emitted.
Double knock
After enabled, the time interval can be set. If the same detector is triggered twice or