OPTICAL UNIT and peripherals
worse.
Disassembling
ATTENTION
Be sure to remove the LAMP UNIT prior to the
OPTICAL UNIT.
1) Remove two screws to detach the LAMP
FAN1.
2) Remove a screw to detach the LAMP FAN1
DUCT.
3)
UNIT and the earth cable (CNGD2).
4) Remove a screw on the IRIS UNIT
(OPTICAL UNIT) to detach the earth cable
(CNGD4).
OPTICAL UNIT
for IRIS UNIT and CNGD4
LWU701i/LW751i/LX801i/LWU601i/LW651i
Service Manual
LWU701i / LW751i / LX801i / LWU601i / LW651i
CAUTION
5 screws (M3x14, w/washer, silver,
0.49±0.1N·m) for OPTICAL UNIT
1
3
5
, 0.4~0.45N·m)
89
Assembling
1) Place the OPTICAL UNIT to the projector
order shown in the drawing. Tightening
convergence worse.
2) Attach and screw down the LAMP FAN1
DUCT.
3) Attach and screw down the LAMP FAN1.
4) Fasten the earth cable CNGD4 with a screw
to the IRIS UNIT.
for LAMP FAN1
4
2
LAMP FAN1 DUCT
CNGD4
in numeric
, 0.69~0.88N·m)
LAMP FAN1
2) Behind the LAMP FAN1
for LAMP FAN1 DUCT
020-000793-01