Christie D Series Service Manual page 42

Hide thumbs Also See for D Series:

Advertisement

Status Monitor
Current
Log
Status
3 LAMP
LAMP
ERR
or
or
ACBLK
96 ACBLK
ERR
4 TEMP
TEMP
ERR
8 FILTR
FILTR
ERR
64
OTHER
OTHER
ERR
(continued on next page)
LWU701i/LW751i/LX801i/LWU601i/LW651i
Service Manual
LWU701i / LW751i / LX801i / LWU601i / LW651i
Indicator Status
Red
Red
Red Red
Red
Red
same time
Red Red
same time
41
Description
The lamp does not light, and there is a possibility
that interior portion has become heated.
Otherwise, AC power supply is unstable (ACBLK).
Turn the power off, and allow the projector to cool
down at least 20 minutes. After the projector has
and then turn the power on again.
Use the unit within the temperature range.
NORMAL MODE: 0 to 40°C
ECO MODE: 0 to 45°C
Turn the power on again. When the lamp turns off in
ballast." is displayed, wrong power unit (ballast) has
If the same indication is displayed after the remedy,
change the lamp referring to the section Replacing
the LAMP UNIT.
The interior portion has become heated.
Turn the power off, and allow the projector to cool
down at least 20 minutes. After the projector has
and then turn the power on again.
Use the unit within the temperature range.
NORMAL MODE: 0 to 40°C
ECO MODE: 0 to 45°C
Is the exhaust air (hot/cold) from peripheral
equipments blowing against the ventilation opening of
projector?
For details on ALTITUDE, refer to ALTITUDE of
SERVICE in the OPTION menu. If the projector is
used with a wrong setting, it may cause damage to the
projector itself or the parts inside.
Turn the power off immediately, and clean or change
. After cleaning or changing the
After the remedy, restart the projector.
Other error has occured.
Use the unit within the temperature range.
NORMAL MODE: 0 to 40°C
ECO MODE: 0 to 45°C
Cleaning and
020-000793-01
LIT MAN SERV D2