Appendix E: Formattig Flash and SRAM
Error Messages
The following alphabetically listed error messages display during error conditions
using XFORMAT.EXE or SRAMDISK.SYS.
Error Message
BATTERY NEEDS REPLACEMENT
Explanation
The XFORMAT program or the SRAMDISK.SYS driver
have detected that the battery power is below 2.5V.
Resolution
Replace the battery.
Error Message
CANNOT READ COMMAND.COM
Explanation
The command processor COMMAND.COM could not be
located.
Resolution
Copy COMMAND.COM to the appropriate directory and
re-invoke XFORMAT.
Error Message
<path> COMMAND.COM WILL NOT BE COPIED TO
THE TARGET
Explanation
A version of COMMAND.COM was found in the top
directory of the <srcdir>.
Resolution
Delete COMMAND.COM from the <srcdir> directory
and re-invoke XFORMAT.
Error Message
INSUFFICIENT SPACE ON TARGET DEVICE
Explanation
The source directory specified is too large to fit onto the
target.
Resolution
Remove some of the files from the source directory.
Error Message
INVALID SLOT NUMBER SPECIFIED
Explanation
The slot number is not a decimal number.
Resolution
Ensure that the slot number does not contain any alpha or
special characters.
INVALID SOURCE PATHNAME
Error Message
Explanation
XFORMAT could not find the directory specified as the
source pathname.
Resolution
Ensure that the source pathname exists.