Hiding Apn Access Data Between Two "Market Partners; Installing/Changing The Internal Modem Assembly - Honeywell EK205-M Operating Instructions Manual

Volume conversion device
Table of Contents

Advertisement

64
"Parameterize
"Parameters" and then its subsections.
In enSuite press the "Disconnect" symbol or

8.1.7 Hiding APN access data between two "market partners"

The EK205-M has two independent interfaces that can be used for remote reading. If both
interfaces are used with GPRS modems by two different market partners (e.g. network operator
and supplier), it is often desired that the users cannot view the APN access data. This prevents
misuse of SIM cards if they are stolen.
To use this function, the following parameter files are available, which can be individually transferred to the
EK205-M using the enSuite software. The settings refer to the access rights for the "Administrator" and the
"Data reader".
1.
Lock APN data - administrator modem at terminals, data reader internal modem
→ The "data reader" party uses the internal interface (2G modem/ethernet card).
2.
Lock APN data - administrator internal modem, data reader modem at terminals
→ Administrator access uses the internal interface (2G modem/ethernet card)
i
If the read and write rights for one party are removed, the return to the factory settings is only
possible with the calibration switch open!
To reset the setting, i.e. the parameters can be seen under both access rights, there is an additional file
Reset locking of APN
Parameter
3:780 – GPRS Access Point Name "APN"
3:781 – APN User Name
3:782 – APN password
Note: Usually the DNS1 and DNS2 are mentioned above for all operators in India unless and otherwise it is
mentioned specifically.
i
The access data stated in the table are examples. They may differ depending on the
SIM or SIM tariff. Please keep in touch with your provider!

8.1.8 Installing/changing the internal modem assembly

The EK205-M comes with the pre-installed ECM-2G-UG350 modem, the below steps are for
installing/changing the modem.
For EK205-M powered with external power supply for the basic device, the external supply must be
switched off before opening the housing.
Danger of death!
For EK205-M powered with external power supply for the basic device, the external
power supply voltage must be switched off before opening the housing, ensure it is not
turned back on and verify that there is no voltage.
online" in the bottom of the navigation window, then click on the plus sign next to
data.
"Disconnect from all
BSNL
Vodafone
bsnl.net
www
- (empty)
- (empty)
- (empty)
- (empty)
Data transfer
devices" to end the test retrieval.
AIRTEL
airtelgprs.com
- (empty)
- (empty)