INSTALLATION AND INITIAL CONFIGURATION

Device installation
The device can be installed on the wall or to cover the 3-module flush-mounting box
(type 503).
We recommend positioning at a height of 1.5 meters from the floor, in an area that
respects as much as possible the average temperature conditions of the entire
environment. Make sure that the distance between the Access Point and the device is
such as to guarantee stable communication.
Avoid installation near doors or windows, in niches, behind doors and curtains or
in positions with excess or total lack of ventilation, to avoid that the reading of the
temperature measured by the probe is in some way offset.
1
4
Connection and association with radiofrequency actuators
1. Power up the device following the connection sheet on page 5.
2. Verify that the device is operating correctly:
heating (factory setting) if it is to control a boiler, air conditioning in the case
of an air conditioner. To change the operating mode, see p. 53.
3. Configure the radiofrequency connection with the remote actuators.
The device allows independent regulation of the temperature,
humidity (in dehumidification mode) and the ventilation unit,
by means of as many remote actuators.
For details on the configuration of the remote actuators see pp. 71-72.
2
- 46 -
SINTESI WALL RF Chronothermostat with humidistat User Manual
3
5
1
1
2
click