Control mode of the generator (boiler or heat pump)
The device allows you to control the generator
(boiler or heat pump) in two ways:
• through the relay (connection via wires)
• through a radiofrequency signal, therefore
without making connections between the device
and the air conditioner (or the boiler)
Setting up:
• rf to choose the radiofrequency control
• reL to select the relay control
Factory value: rf (radiofrequency).
Note: the configuration and the test of the radiofrequency connection are carried out
accessing the RF menu (see page 71). This menu is active only if the system control is
set to rf, while it is not active if it is set to reL.
Note: the control of the dehumidifier and any controlled mechanical ventilation unit can
only be done by means of radiofrequency signals.
- 68 -
SINTESI WALL RF Chronothermostat with humidistat User Manual