Perform a reset to cancel the settings made and bring the device back to the
conditions in which it appears as soon as it has been removed from the packaging.
To reset:
1. from the initial screen, press and hold the key
The CLOCK indication flashes.
2. press and hold down the keys
appears on the display.
3. when the display shows all the segments, keep the key
"DEF" appears
Initial screen
To reset if the key lock is active and you do not know the unlock password, you
must remove and restore power and, when the display shows all the segments,
keep the key
Operation mode
Regulation type
Differential (on/off)
Band (proportional)
Period (proportional)
Adjustment command
Antifreeze temperature OFF
MEV

DEVICE RESET

and
3s
SET
Configuration
menu
pressed until "DEF"appears.
heating
(winter)
on/off
0.3 °C
0.5 °C
10 minutes
rF (via RF signal)
6 °C
always active
SINTESI WALL RF Chronothermostat with humidistat User Manual
to enter the configuration menu.
simultaneously until "RES"
3"
+
SET
Adj. ADJ temperature
Min. settable temperature
Max. adjustable temperature
Hour meter operation
Automatic summer time change
Backlighting
Key lock password
- 74 -
pressed until
3s
0 °C
2 °C
50 °C
0 h
/
active
(according to EU rules)
active
disabled