SET MENU - TEMPERATURES T1, T2, T3 SETTING
Access the SET menu to change the values of the 3 temperatures used in automatic
operation. The factory setting includes:
• T1 = 5°C, T2 = 15°C, T3 = 18°C (heating/winter operation )
• T1 = off, T2 = 23°C, T3 = 25°C (conditioning/summer operation
How to change the temperature values T1/ T2/ T3
Initial screen
Change T1
To exit the temperature change:
• press the key
• press the key
Note: temperature values between L0 (minimum value) and kI (maximum value)
are allowed.
These factory values are: L0 = 2°C, kI = 50°C but can be modified through the ADV
menu.
Note: the condition T1 ≤ T2 ≤ T3 must be respected.
3s
SET
Configuration menu
Change T2
once to return to the configuration menu
twice to exit the menu and return to the initial screen
SINTESI WALL RF Chronothermostat with humidistat User Manual
- 60 -
)
x2 times
SET Menu