Configuration Error Codes - Banner ZMX Series Instruction Manual

3d time of flight sensor
Table of Contents

Advertisement

Sensor Fault
Description
Code
32
Laser Power Write Error
1000
Acquisition Error 3
1011–1017
Internal Flash Error 1–7
30000-32000
Boot Loader Error

6.3.2 Configuration Error Codes

The following is a list of possible error codes.
Modbus TCP: The codes are from input register 22 (holding register 1022).
EtherNet/IP: The codes are from word 21 in the PLC Input (ZMX Output) Assembly Instance
Error Code
Description
110
Illumination Power < 1
111
Illumination Power > 100
120
Invalid Trigger Mode
130
Trigger Period < 200 ms
131
Trigger Period > 60000 ms
140
Pitch Angle < -4500
141
Pitch Angle > 4500
150
Roll Angle < -4500
151
Roll Angle > 4500
160
Yaw Angle < -18000
161
Yaw Angle > 18000
300
Invalid Discrete Polarity
2000
Anchor Point X < -2500 mm
2001
Anchor Point X > 2500 mm
2010
Anchor Point Y < -2500 mm
2011
Anchor Point Y > 2500 mm
2020
Anchor Point Z < -2500 mm
2021
Anchor Point Z > 2500 mm
2030
Bin Length X < 50 mm
2031
Bin Length X > 5000 mm
2040
Bin Width Y < 50 mm
2041
Bin Width Y > 5000 mm
2050
Bin Height Z < 50 mm
2051
Bin Height Z > 5000 mm
2052
Invalid Bin Height
2060
Fill Level Setpoint < 0%
2061
Fill Level Setpoint > 200%
2080
Peak Height Setpoint < 0
Recommended Solution
Reboot the sensor
If the fault persists, call Banner Customer Support
Reboot the sensor
If the fault persists, call Banner Customer Support
Call Banner Customer Support
Call Banner Customer Support
www.bannerengineering.com - Tel: + 1 888 373 6767
ZMX Series 3D Time of Flight Sensor
45

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zmx-3de2500hf-q7

Table of Contents