Banner Q3XTBLD-Q8 Quick Start Manual

Banner Q3XTBLD-Q8 Quick Start Manual

Q3x series laser contrast sensor
Hide thumbs Also See for Q3XTBLD-Q8:

Advertisement

Q3X Laser Contrast Sensor
Quick Start Guide
Laser Expert
diffuse sensor with bipolar (1 PNP & 1 NPN) output. Patent pending.
This guide is designed to help you set up and install the Q3X Sensor. For complete information on programming,
performance, troubleshooting, dimensions, and accessories, please refer to the Instruction Manual at
www.bannerengineering.com. Search for p/n 181485 to view the manual. Use of this document assumes familiarity with
pertinent industry standards and practices.
WARNING: Not To Be Used for Personnel Protection
Never use this device as a sensing device for personnel protection. Doing so could lead to
serious injury or death. This device does not include the self-checking redundant circuitry necessary
to allow its use in personnel safety applications. A sensor failure or malfunction can cause either an
energized or de-energized sensor output condition.
Features
Figure 1. Sensor Features
Display and Indicators
Figure 2. Display in Run Mode
In Run mode, the 3-digit, 7-segment display provides real time information about signal strength for all models and target
position for models with a fixed background suppression distance. The numeric value of 0 to 990 represent the amount of
the received light divided by the threshold, and represents the excess gain of the sensing event expressed as a percentage
of the switch point. This value is called normalized signal strength (NSS). A NSS display range of 999 indicates a saturated
received light signal, meaning that low contrast detection is not possible.
In single threshold teach modes (Two-Point Static, Dynamic, Light Set, or Dark Set), the output switches at a displayed
value of 100 (excess gain of 1.0).
For models with a specified background suppression distance,
the background suppression distance and is being suppressed. In Light Operate mode, the output switches off when
displays. For the LD50 models, the sensor's output state when displaying
By default, the sensor treats a target in the background as a dark signal and honors the LO/DO selection.
Original Document
181486 Rev. D
1
2
3
21 May 2015
1. Output Indicator (Amber)
2. Display
3. Buttons
1. Stability Indicator (STB = Green)
2. Active TEACH Indicators
DYN = Dynamic TEACH selected (Amber)
WND = Symmetric window thresholds are
active (Amber)
indicates that a target is present at a distance beyond
can be controlled using the
menu.
181486

Advertisement

Table of Contents
loading

Summary of Contents for Banner Q3XTBLD-Q8

  • Page 1 Q3X Laser Contrast Sensor Quick Start Guide ™ Laser Expert diffuse sensor with bipolar (1 PNP & 1 NPN) output. Patent pending. This guide is designed to help you set up and install the Q3X Sensor. For complete information on programming, performance, troubleshooting, dimensions, and accessories, please refer to the Instruction Manual at www.bannerengineering.com.
  • Page 2 Q3X Laser Contrast Sensor A displayed value of indicates no light received or a loss of signal. In Window Set teach mode, the value 100 represents the taught signal strength. The displayed value is the percentage of the received light divided by the taught signal strength. The output switches at displayed values above and below 100 as determined by the user-selected window offset percentage.
  • Page 3: Laser Description And Safety Information

    Q3X Laser Contrast Sensor Laser Description and Safety Information CAUTION: Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure. Do not attempt to disassemble this sensor for repair. A defective unit must be returned to the manufacturer.
  • Page 4: Wiring Diagram

    Q3X Laser Contrast Sensor Wiring Diagram 10-30V dc – Load Load 1 = Brown Input 2 = White Wire 3 = Blue 4 = Black NOTE: Open lead wires must be connected to a terminal block. 5 = Gray NOTE: The input wire function is user-selectable; see the Instruction Manual for details. The default for the input wire function is off (disabled).
  • Page 5: Manual Adjustments

    Q3X Laser Contrast Sensor 1. Press and hold TEACH for longer than 2 seconds to start the selected TEACH mode. 2. Present the target. 3. Press TEACH to teach the target. The target is taught and the sensor waits for the second target, if required by the selected TEACH mode, or returns to Run mode.
  • Page 6: Specifications

    Sensing Suppression 10 to 30 V dc Range Distance Power and Current, exclusive of load Q3XTBLD-Q8 0 to 300 mm Not Applicable Supply Power: < 675 mW (11.81 in) Current consumption: < 28 mA at 24 V dc Supply Protection Circuitry...
  • Page 7 Banner Engineering Corp. Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period.
  • Page 8: Sensor Menu Map

    Q3X Laser Contrast Sensor Sensor Menu Map Top Menu Sub Menu BOTH sets selection BOTH Output Operation Light Operate default setting) Dark Operate BOTH Teach Process Selection Two-Point Static Teach Dynamic Teach Window Set Light Set Dark Set Offset Percentage BOTH (min, 10, 20, 30, 40, 50) - Window &...

This manual is also suitable for:

Q3xtbld50-q8Q3xtbld100-q8

Table of Contents