WESTECH Solax X3-HYBRID G4 Manual page 18

Table of Contents

Advertisement

Installation
Ø
Step 2: hang the inverter on the bracket
c) Insert expansion bolt into the hole, use rubber hammer to knock the
expansion screw bolt into the wall;
d) The bracket is aligned with the screw uses the inner hexagonal wrench to
screw the tapping screw until the expansion bolt "bang" is heard.
Expansion bolts, Tapping screws,
nut, Gasket,
30
Φ10 Drill
(Depth: 80 mm)
b)
Hammer
c)
d)
Ø
Step 3: Tighten the inverter and bracket
e ) Hang the buckle on the inverter to the corresponding position of the
backplane;
f ) Use the inner hexagonal wrench to tighten the inner hexagonal screw
on the right side of the inverter.
e)
f)
Installation
Inner hexagonal wrench
N· m
(Torque:1.2±0.1
)
31