8 Troubleshooting

8.1 Troubleshooting
This section contains information and procedures for resolving
possible problems with X3-Hybird G4, and provides you with
troubleshooting tips to identify and solve most problems that may
occur in X3-Hybrid G4. This section will help you narrow down the
source of any problems you may encounter. Please read the
troubleshooting steps below.
Check the warning or fault information on the system control panel
or the fault code on the inverter information panel. If a message is
displayed, log it before doing anything further.
Try the solutions indicated in the table below.
Number
Overcurrent fault.
Wait for a while to check if you're back to normal.
IE 001
TZ Protect Fault
Disconnect PV+ PV- and batteries, reconnect.
Or ask for help from the installer if itcan not return to normal.
Check battery input voltage if it's within normal range
Grid Lost Fult
IE 002
Or ask the installer for help.
Power grid voltage overrun
• ait a moment, if the utility returns to normal, the system will reconnect.
W
Grid Volt Fault
IE 003
• lease check if the grid voltage is within normal range.
P
• r ask the installer for help.
O
Electricity frequency beyond range
Grid Freq Fault
If the utility returns to normal, the system reconnects.
IE 004
Or ask the installer for help.
PV voltage out of range
Check the output voltage of the PV panel
IE 005
PV Volt Fault
Or ask the installer for help.
• press the "ESC" key to restart the inverter.
IE 006
Bus Volt Fault
• Check that the PV input open circuit voltage is in the normal range.
Or ask the installer for help.
Battery voltage fault
Bat Volt Fault
Check battery input voltage if it's within normal range
IE 007
Or ask the installer for help.
• The grid voltage was out of range in the last 10 minutes.
The system will return to normal if the grid returns to normal.
IE 008
AC10M Volt Fault
Or ask the installer for help.
Troubleshooting
111