Setting
a ) Safety Code
Users can set safety standards according to different countries. There are
now 1 standards to choose from. (There may be changes in the future,
please refer to the screen display)
Item
Standard
ARN 4105
1
OverVoltage_L1
UnderVoltage_L1
OverFreq_L1
UnderFreq_L1
Vac 10min Avg
OverVoltage_L2
UnderVoltage_L2
OverFreq_L2
UnderFreq_L2
OverFreq_L2
UnderFreq_L2
Tovp_L1
Tuvp_L1
Tofp_L1
b ) Grid Parameters
Here you can set the protection value of grid voltage and frequency.
The default value is the specified value under the current safety
regulations, and the user cannot change it.
The display content will be displayed according to the requirements
of local laws and regulations, which are constantly increasing. Please
refer to the contents displayed on the inverter screen.
Grid
>OverVoltage_L1
0.0V
98
Country
German
Tovp_L2
Tuvp_L2
Tofp_L2
Tufp_Fast
Reconnection Time
Checking Time
W(Gra)
OFPL_StartPoint
OFPL_SetRate
OFPL_DelayTime
UFPL_StartPoint
UFPL_SetRate
UFPL_DelayTime
Grid
>UnderVoltage_L1
0.0V
Grid
>OverFreq_L1
0.0Hz
Grid
>Vac 10min Avg
0.0V
c ) Charger
Here the user can set the parameters of charger on this page, the
inverter is compatible with both lithium battery. Users can set the
charge & discharge parameters.
For the detailed parameters, please refer to below table.
Charger
Charge Max
Current
25A
d ) Export Control
This feature allows the inverter to control the amount of electricity
output to the grid.
The factory value is the default and can be changed by the user. The
user value set by setup must be less than the maximum. If the user
does not want to supply power to the grid, set it to 0.
Export Control
User value:
e ) Meter/CT Settings
The user needs to select the CT or electricity meter to connect the
inverter here. Select the address of the meter. CT does not need to select
the address.
CT/Meter Setting
>Select
Meter
Setting
Grid
>UnderFreq_L1
0.0Hz
Grid
>OverVoltage_L2
0.0V
Charger
Discharge Max
Current
25A
0W
CT/Meter Setting
>Meter 1Addr:
xxxxxxxx
99