RDL-3000 Ellipse TMA Sector Controller Installation Guidelines
Class I
All External Circuits
All equipment must be grounded
Le RDL-3000 du matériel a été testé pour la conformité aux normes de sécurité
électriques indiquées dans le tableau suivant:
Classe I
Tous les circuits externes
Tous les équipements doivent être mis à la terre

UL Information

The suitability of the supplied Ethernet cable is subject to the approval of Authority
Having Jurisdiction and must comply with the local electrical code.
The equipment must be properly grounded according with NEC and other local
safety code and building code requirements.
Reminder to all the BWA system installers: Attention to Section 820-40 of the NEC
which provides guidelines for proper grounding and, in particular, specifies that the
cable ground shall be connected to the grounding system of the building, as close to
the point of cable entry as is practical.
RDL-3000 system must be installed in compliance with relevant articles in National
Electrical Code-NEC (and equivalent Canadian Code-CEC) including referenced
articles 725, 800 and 810 in NEC.
RF coaxial cable connecting an antenna to the RDL-3000 system must comply with
the local electrical code.
To meet the over-voltage safety requirements on the telecommunications cables, a
minimum 26 AWG telecommunication line cord must be used.
Pour être en conformance avec les exigences finies de sûreté de sur-tension sur les
câbles de télécommunications un fil de télécommunication ayant un calibre minimum
de 26 AWG doit être utilisé.

Lightning Protection / Protection Contre la Foudre

When installed, this equipment is to be connected to a Lightning/Surge Protection
Device that meets all applicable national safety requirements. Before Ethernet cables
enter buildings, voltages shall be clamped down to SELV by approved type primary
protectors.
WARNING: The information provide in this user manual consists of general
recommendations for installation the system equipment. The wireless equipment must
be installed by a qualified professional installer who is knowledgeable of the
requirements of installing outdoor radio equipment and follows local and national codes
for electrical grounding and safety. Failure to meet safety requirements and/or use of
non-standard practices and procedures may result in personal injury and/or damage to
equipment.
The system must be properly grounded to protect against power surges and
accumulated static electricity. The user is responsible to install this device in accordance
with the local electrical codes: correct installation procedures for grounding the unit,
mast, lead-in wire and discharge unit, location of discharge unit, size of grounding
conductors and connection requirements for grounding electrodes.
70-00159-02-00

Table 1: Notice - Electrical Safety Specifications

Table 2: Avis - Spécifications de sécurité électrique
Proprietary Redline Communications © 2014
EN 60950-1
TNV-1 as defined in EN 60950-1
EN 60950-1
TRT-1 tel que défini dans la norme EN
60950-1
Page
11
of 59
July 18, 2014