Do not disconnect any output leads or connectors between the batteries and the charger when the charger
is on. To stop a charge in progress, always unplug the extension cord from the AC power source.
Recharge batteries in a well-ventilated area only. Do not charge batteries near fire, spark or other potential
ignition sources. Batteries may emit highly explosive hydrogen gas while charging. Failure to properly
ventilate the charge gasses could result in death or serious injury. Always charge aerial work platform
batteries away from flammable materials.
ALWAYS avoid contact with battery acid. Battery acid causes serious burns and should be kept away from
skin or eyes. If contact occurs, flush with water and consult a physician immediately.
When there is a fault, the LED indicator flashes in various colours depending on the type of
alarm :
State of flashing indicator
Red
Yellow
Green
Red-Yellow
Red-Green
Red-Yellow-Green
In case of an alarm, the charger stops supplying power.
When the battery charge reaches 80% of capacity, the yellow 80% CHARGED indicator LED
will become lit and the green CHARGING indicator LED will begin to flash.
Unplug the extension cord from the outlet and the charger receptacle on the aerial work
platform. Store the extension cord for next use.
N.B.-:-A
PLATFORM
Maintenance load :
When the charger is connected to the mains for more than 48 h (hours), a new charging cycle
starts up at the end of the previous charging cycle in order to offset self-discharge.
Charge interruption :
To turn off the charger, disconnect it from the mains supply.
Should the machine need to be operated during a charging cycle, first diconnect the charger.
This may reduce the life span of the batteries. Re-connect the charger once the operation is
over.
4001001030
Type of alarm
Battery presence
Temperature probe
Specified time
Battery current
Battery voltage
Temperature
LWAYS UNPLUG THE BATTERY CHARGER POWER CORD BEFORE MOVING THE AERIAL WORK
. F
AILURE TO DISCONNECT POWER CORD COULD CAUSE DAMAGE TO THE EQUIPMENT
E 06.20
Description (Action)
Battery not connected or not compliant : Check connection
or rated voltage.
Temperature probe disconnected while charging or outside
the functional range : Check connection and measure
battery temperature.
Phase 1 or 2 is longer than the maximum allowed time :
Check battery capacity.
Loss of output current control : Faulty control logic.
Loss of output voltage control : Battery disconnected or
faulty control logic.
Overheating of semiconductors : Check fan operation.
.
USA / GB
97
A
B
C
D
E
F
G
H
I