Connecting the RF OUT Ports

Follow these steps to connect the RF OUT ports.
CAUTION:
Turning on the MQAM with default RF output level may cause RF
interference with the services of other units connected to the network.
Therefore, set the RF output frequency and RF output level before you
connect any RF OUT ports to the network.
Important! We strongly recommend that you configure and adjust
frequencies from the Set Up GQAM window on the DNCS. See
Provisioning the MQAM on the DNCS (on page 38) for detailed
instructions.
1
Refer to your network wiring diagram to connect the MQAM properly.
Locate the RF OUT or IF OUT ports on the back panel of the MQAM.
2
3
Connect one end of a 75 Ω coaxial cable to each port to be used for the MQAM.
4
Verify that you have established the correct output level for the RF OUT ports by
completing the following steps:
a
Connect the MQAM to a spectrum analyzer to measure radio frequency
levels.
b Set the RF output levels from the front panel of the MQAM.
Provision the MQAM from the DNCS.
c
5
Connect the other end of each 75 Ω coaxial cable to the distribution plant.