Cylinder And Lever Installation; Removing Cylinder Handle - Assa Abloy Yale 5300LN Series Parts And Service Manual

Grade 2 key-in-lever cylindrical lockset
Table of Contents

Advertisement

INSTALLATION INSTRUCTIONS
5300 GRADE 2
KEY-IN-LEVER
CYLINDRICAL
LOCKSET
Outside
Lockbody Assembly
Attaching
Screws
81-2012-0416
To Remove Cylinder Handle
1. Insert key and rotate counterclockwise 45°.
2. Depress retainer with tool provided.
3. Slide lever off lock. (Also applies to inside lever
of 5321LN lock function.)
3
1
Page 22
Finish Care
This lockset is designed to provide the highest standard of product quality
and performance. Care should be taken to ensure a long-lasting finish.
When cleaning is required use a soft, damp cloth. Using lacquer thinners,
caustic soaps, abrasive cleaners or po ishes could damage the coating
and result in tarnishing.
Through Bolts (2) Req'd
81-0012-0584
#10-32 UNF-2A
2-1/2" (2" for 5328 & 5329) on 1-3/8" & 1-3/4" Doors
3" (2-1/2" for 5328 & 5329) on 2" & 2-1/4" Doors
To Replace or Install Cylinder
1. Remove the sleeve from inside the shank or from the old cylinder.
2. Slide cylinder into sleeve.
3. Rotate key 45° counterclockwise. Depress retainer plate, push the
handle onto the shank until fully seated. Pull on handle to ensure
properly seated.
2
(
Note:
installed or the security of the lock will be
compromised.)
September 2003
l
Inside Rose
Support Assembly
14-5301-0002
Rose Scalp
14-5300-2024
14-5300-3024
Connecting Bar
Cylinder Sleeve
14-5305-9078
Cylinder and Sleeve must be properly
Interchangeable
Core Cylinder
1210 6-Pin
Inside Lever Handle
Yale® Cylinder
5300LN Series Parts & Service Manual