Assa Abloy Yale NTM612-ZW3 Manual
Assa Abloy Yale NTM612-ZW3 Manual

Assa Abloy Yale NTM612-ZW3 Manual

Hide thumbs Also See for Yale NTM612-ZW3:

Advertisement

Quick Links

Yale Locks
Z-Wave Plus ™ v2 System Integrators Guide
Yale NexTouch Sectional Mortise Commercial Grade Locks
NTM612-ZW3, NTM617-ZW3, NTM622-ZW3, NTM627-ZW3, NTM632-ZW3,
NTM637-ZW3, NTM642-ZW3, NTM647-ZW3, NTM612-NN-ZW3, NTM617-NN-ZW3,
NTM622-NN-ZW3, NTM627-NN-ZW3, NTM632-NN-ZW3, NTM637-NN-ZW3,
NTM642-NN-ZW3, NTM647-NN-ZW3
Document Revision: 1.3
May 2023
1

Advertisement

Table of Contents
loading

Summary of Contents for Assa Abloy Yale NTM612-ZW3

  • Page 1 Yale Locks Z-Wave Plus ™ v2 System Integrators Guide Yale NexTouch Sectional Mortise Commercial Grade Locks NTM612-ZW3, NTM617-ZW3, NTM622-ZW3, NTM627-ZW3, NTM632-ZW3, NTM637-ZW3, NTM642-ZW3, NTM647-ZW3, NTM612-NN-ZW3, NTM617-NN-ZW3, NTM622-NN-ZW3, NTM627-NN-ZW3, NTM632-NN-ZW3, NTM637-NN-ZW3, NTM642-NN-ZW3, NTM647-NN-ZW3 Document Revision: 1.3 May 2023...
  • Page 2: Table Of Contents

    Contents Revision History ..................4 Yale Z-Wave Plus ™ Product Info ..............5 Network Operations ..................5 Enroll/Add device to network (SmartStart) ........... 5 Enroll/Add device to network (Classic Inclusion Mode) ........5 Un-enroll/Remove device from network (Exclusion Mode) ........ 5 Factory Reset ...................
  • Page 3 Command Class Indicator, Version 3* ............27 Command Class Basic, Version 2* ............. 28 * This command class requires security.
  • Page 4: Revision History

    Revision History Rev. Details Initial Release Added description of what other features are affected when Passage Mode and Escape Return Mode features are enabled. Fixed Minimum value for Auto Relock Time and fixed Default Value for Auto Relock Feature • Added -NN (No NFC) SKUs •...
  • Page 5: Yale Z-Wave Plus ™ Product Info

    Yale Z-Wave Plus ™ Product Info Manufacturer ID: ASSA ABLOY (0x0129) Z-Wave™ Device Type: Door Lock Keypad Z-Wave™ Role Type: Listening Sleeping Slave (LSS) Network Operations Enroll/Add device to network (SmartStart) SmartStart enabled products can be added into a Z-Wave™ network by scanning the Z-Wave™...
  • Page 6: Factory Reset

    • Press the key followed by the key. When the Yale lock is unenrolled/excluded from the network through the device menu mode, any changes previously made to the user code database and configuration settings will be retained, as opposed to set back to defaults. Factory Reset •...
  • Page 7: Command Class Manufacturer Specific, Version 2

    * This command class requires security. The Manufacturer Specific command class reports the following information: • Manufacturer ID: 0x0129 o This is the manufacturer ID assigned to ASSA ABLOY. • Product ID: o The Product ID can be used to differentiate between hardware platforms, as well as between ZW2 and ZW3.
  • Page 8: Command Class Security, Version 1

    0x4A35 for NTM637-NN -ZW3 (2nd Generation Key free with ▪ Deadbolt Push Button Interface Mortise Lock with No NFC) 0x4A3A for NTM642-NN -ZW3 or Default ID for NTM Touch ▪ Screen Lock (2nd Generation Key free Touch Screen Interface Mortise Lock with No NFC) 0x4A3F for NTM647-NN -ZW3 (2nd Generation Key free with ▪...
  • Page 9: Command Class Power Level, Version 1

    Command Class Power Level, Version 1* * This command class requires security. This command class has been implemented per the Z-Wave™ Specification. The Power Level command class was implemented to allow controllers to set the transmit power for the door lock. This could be useful in large networks with many nodes, so that the lock can find working routes back to the controller while transmitting at a lower power.
  • Page 10: Command Class Battery, Version 1

    For Firmware Target 0, the Firmware 0 Version (0x02) and Sub version (0x22) translate to module firmware decimal value of “2.34”. For Firmware Target 1 (the data under vg1), Firmware Version (0x2C) and Sub version (0x00) translate to lock firmware decimal value of “4.3.00”. Command Class Battery, Version 1* * This command class requires security.
  • Page 11: Command Class Door Lock Logging, Version 1

    Command Class Door Lock Logging, Version 1* * This command class requires security. This command class has been implemented per the Z-Wave™ Specification. Command Class Schedule Entry Lock, Version 3* * This command class requires security. Yale locks support Year Day Schedule types and Daily Repeating Schedule types. Yale locks allow the controller to apply multiple schedules to a single user.
  • Page 12 It should be noted that the lock’s operation mode (called “User Code Keypad Mode” in this command class) can be modified through Version 2 of this command class, or through parameter 8 of the Configuration command class. This is the only parameter that can be modified through more than one command class.
  • Page 13 Yale locks support the following User ID Status values: Table 3 - User ID Status User Code CC v1 vs v2 User ID Status User Code CC v1 Set User Code CC v1 Report Value Description Value Value Available 0x00 0x00 Enabled / Grant Access 0x01...
  • Page 14 User ID User Code CC v2: Extended User Code CC v2: Extended User Status User Code Set Code Report Value Description Value Value Available 0x00 0x00 Enabled / 0x01 0x01 Grant Access Disabled 0x02 0x02 Messaging: The user code is accepted, but the lock does not grant access to the...
  • Page 15: Command Class Time Parameters, Version 1

    Command Class Time Parameters, Version 1* * This command class requires security. The controller must set the Time Parameters in the lock anytime the lock loses power. After 10 seconds from lock enrollment, if there are no messages from the controller the lock will initially request the Time (by sending Time Get and Time Parameter Get commands).
  • Page 16: Command Class Firmware Update Meta Data, Version 5

    Firmware Target 0 is used to determine the correct Z-Wave™ processor image to download. ID 1 is always 0xA5, to signal this is an ASSA ABLOY Z-Wave™ image, and ID 2 is specific to the region, with the lower nibble being 0x0 and the upper nibble being the value in Table 4 - Region-Specific Values for Firmware ID 0.
  • Page 17: Command Class Association, Version 2

    The following is the time it takes for each product to complete OTA image apply phase: • For Z-Wave™ Radio Chip, ~10 seconds • For NTM612/617/622/627/632/637/642/647-ZW3 (2nd Generation Mortise Locks), ~23 minutes • For NTM612/617/622/627/632/637/642/647-NN- ZW3 (2nd Generation Mortise Locks with No NFC), ~23 minutes Command Class Association, Version 2* * This command class requires security.
  • Page 18: Command Class Association Group Info, Version 3

    Command Class Association Group Info, Version 3* * Command Class Requires Security Yale locks support the Lifeline Association Group. Table 5 - Association Table Group ID Maximum Nodes Description Commands • Command Class Battery Battery Report • Command Class Configuration Configuration Report •...
  • Page 19 The following are the actions to trigger the reports: Table 6 – Lifeline Report Trigger Table Report Command RF Trigger Manual Trigger Battery Report Any RF Lock Operation when lock is Any manual/keypad Lock Operation under the battery thresholds when lock is under the battery thresholds or Power Cycle Lock Configuration Report Configuration Set...
  • Page 20: Command Class Notification, Version 8

    Command Class Notification, Version 8* * This command class requires security. Table 7 - Notification Table Alarm Alarm Notification Alarm Reports Description Event type Level Type 0x (01 – Where Alarm level represents user slot Keypad Lock 0x12 0x06 0x05 number max users) 0x(01-max...
  • Page 21 0x(01-max User was deleted. Alarm level = user 0X0D users) slot number (single) User deleted 0x21 0x06 0X0C 0x00 ¹ All User codes were deleted (all) A Non-Access Code was entered at the 0x(01-max lock. Non-Access 0x26 0x06 0xFE users) Where alarm level represents user slot number Lever was rotated.
  • Page 22 Alarm Level = 0xFFFF then all users were affected. Year Day Schedule 0x(01-max Year Day Schedule(s) were Enabled/Disabled 0x63 users) Enabled/Disabled for User ID specified 0x06 0xFE in Alarm Level. If Alarm Level = 0xFFFF then all users were affected. All Schedule Types 0x(01-max All Schedule Types were Set...
  • Page 23 Power to the lock was restored and the Door Lock needs Time locks RTC was cleared. The controller set / RF Module Power 0x82 0x00 0x08 0x01 should set the time to ensure proper Cycled logging. A disabled user pin code was entered at Disabled user entered 0x(01-max 0x83...
  • Page 24: Command Class Configuration, Version 4

    Command Class Configuration, Version 4* * This command class requires security. Table 8 - Configurable Parameters Length Configuration Properties Info of Info String Name Length (max length Default Param. allowed Num. is 90) 0x01 (High 0x03 0x01 (High Set Volume Level to high (1), Volume 1 byte Volume)
  • Page 25 Adjust the time your lock is Shut down 0x0A (10 0x84 (132 0x3C (60 1 byte shutdown after reaching its time seconds) seconds) seconds) wrong code entry limit. 0x00 0x03 0x00 Set the Operating Mode to Operating 1 byte (Normal (Passage (Normal normal mode, vacation mode,...
  • Page 26 Privacy Mode 0x00 0xFF 0x00 Enable or Disable Privacy Mode 1 byte with Deadbolt (Disable) (Enable) (Disable) with Deadbolt feature Set Lock Body Sensors: DPS, Lock Body 0x00 0xFF (All 0xFF (All 1 byte Deadbolt, and Lever Rotate to Alarms Mask⁷ (Disable) Alarms) Alarms)
  • Page 27: Command Class Application Status, Version 1

    Command Class Application Status, Version 1 This command class has been implemented per the Z-Wave™ Specification. Command Class Transport Service, Version 2 This command class has been implemented per the Z-Wave™ Specification. Command Class Supervision, Version 1 This command class has been implemented per the Z-Wave™ Specification. Command Class Indicator, Version 3* * This command class requires security.
  • Page 28 Command Class Basic, Version 2* * This command class requires security. This command class is mapped to Door Lock CC: Table 11 – Basic Mapping Overview Basic Command Door Lock Mapped Command Basic Set (Value) Door Lock Operation Set (Door Lock Mode) Basic Report (Current Value = 0x00) Door Lock Operation Report (Door Lock...

Table of Contents