Functions Only; Dummy Trim Installation; Strike Installation (Wood Frames Only); Troubleshooting - Assa Abloy Yale 5300LN Series Parts And Service Manual

Grade 2 key-in-lever cylindrical lockset
Table of Contents

Advertisement

INSTALLATION INSTRUCTIONS

Dummy Trim Installation

Secure the Rose Support assembly to the door using screws
and washers provided and install the rose scalp and inside
lever.
Through Bolts
Inside Rose
Support Assembly
Washers
Rose Scalp

8. Strike Installation (Wood Frames Only)

A. Close door and mark a horizontal line from the center of
the template to the frame of the door.
B. Measure half the thickness of the door; mark this same
distance with a vertical line starting from the stop side of
the frame and where both lines cross make a 1" (26mm)
diameter hole and 1/2" (13mm) in depth.
C. Align the holes of the strike with the vertical line, trace
the outline of the strike and mortise to 1/16" (1.6mm)
depth. Attach the strike with two screws (provided).
TEST THE OPERATION OF THE LOCKSET
Cycle the lock in both the locked and
STOP
unlocked positions. If lock functions smoothly
when door is open, but binds when closed,
check door and frame alignment. If problems
are found see troubleshooting below.

Troubleshooting

1. Check door.
2. Check hinges. They should not be loose or have excessive
wear on knuckles.
3. Latchbolt will not deadlock.
Either strike is out of line or gap between door and jamb is
too great. Realign strike or shim strike out towards flat
area of latchbolt.
4. Latchbolt does not retract or extend properly.
Latchbolt tail and retractor not properly positioned.
A. Remove lockset. Look through 2-1/8" hole and verify
latchbolt tail centered between top and bottom of hole.
B. Remove latchbolt and insert lockset, look through latch
hole and verify retractor mouth centered in hole. Adjust
outside rose plate if not (See #5 on Page 21).
C. Rebore holes if necessary to line up retractor and tail.
5300LN Series Parts & Service Manual
5428LN & 5329LN Functions Only
Adjust for Door Thickness
Turn Blank Rose until "A" dimension is achieved for
door thickness. (See table).
Studs should be aligned with through-bolt holes in
door.
Inside Lever
497
Optional Strike Box
#
202
Attaching Screws
81-2012-0620-FINISH
#12-12-24x1"
Door Must Not Bind
Door Must Not Sag
September 2003
Door
"A"
Thickness
1/4"
1-3/8"
1-3/4"
7/16"
2"
9/16"
2-1/4"
11/16"
"A"
STRIKES
495
Standard Strike Box
14-5301-1033-048
Attaching Screws
81-2012-0416-FINISH
#8-8-32x3/4"
Door Must Not Warp
Door Must Swing Freely