Association Table Group ID Maximum Nodes Description Commands Command_Class_Battery, Battery_Report ; Command_Class_Notification, Notification_Report; Lifeline Command_Class_Configuration, Configuration_Report; Command_Class_Device_reset_locally, Device_Reset_locally_notification Notifications Table: Alarm Notification Alarm Reports Alarm Level Description Event type Type Master code was 0x00 0x06 0x12 Master Code changed at keypad changed.
Page 5
RF Operate Lock 0x18 0x01 by RF module 0x06 0x03 Where Alarm level 0x (01 – max Keypad Lock 0x12 represents user slot 0x06 0x05 users) number A Non Access Code was entered at the 0x(01-max lock. Non Access 0x26 0x06 0xFE users)
Page 6
user is out of schedule this alarm will be sent instead of the non- access alarm. 0x00 Door Opened 0x06 0x16 0x01 Door Closed 0x06 0x17 Door Position Door Propped (Door 0x2B Sensor Open for longer than 0x02 0x06 0xFE configurable door propped time) Daily Repeating...
Configurable Parameters Configuration Parameter Size Description Parameters Number Level control, 1 = High Volume, 2 = Low Volume, 3 = Silent mode on/off 1 1 byte Silent. Default is 1 or High Volume Auto Relock on/off 2 1 byte 0x00 = OFF, 0xFF = ON default is 0x00 or OFF Auto Relock time 3 1 byte 1 to 180 seconds default is 03 seconds...
Page 8
0x00 = OFF, 0xFF = ON Default is 0xFF or ON. Used to enable/disable door condition alarms for locks DPS Alarms(Ax sensor) 19 1 byte that support a door position sensor. Any lock that does not support DPS will always report 0x00. 0x00 = NO deadbolt , 0xFF = YES deadbolt Read only parameter.