Expanding and assigning parameters to the device
6.6 Installing and removing drives
Maximum vibration load for drives in the respective installation location
Note
If the device is permanently installed or mounted on telescopic rails, it may only be subjected
to the following vibration loads during operation.
The restrictions do not apply to the use of SSD.
Drives in drive cage type B
Drives in drive cage type B may be exposed to the following maximum vibration loads during
operation:
• 10 ... 58 Hz: 0.015 mm
• 58 Hz to 500 Hz: 2 m/s
Vibrations must not exceed 500 Hz.
Permissible number of drives depending on ambient air temperature
Drive type
2.5" SATA
3.5" SATA
Drive type
2.5" SATA
3.5" SATA
Drive type
2.5" SATA
3.5" SATA Enterprise
124
2
Ambient temperature
+0 to +50 °C
2 drives
1 drive
Ambient temperature
+0 to +45 °C
2 drives
2 drive
Ambient temperature
+5 to +35 °C
1 drive
2 drives
Operating Instructions, 09/2022, A5E52254141-AA