Restarting Loader After Alarm Procedure - Mazak STX SC L PLUS CONTROL Training Manual

Table of Contents

Advertisement

RESTARTING LOADER AFTER ALARM PROCEDURE

If an alarm occurs which requires pressing reset, perform the following:
1>
Press "command" and note which line was being executed.
2>
Press "reset".
3>
Correct the cause of the alarm.
4>
Edit the "part" sub-program:
5>
Using the "seq. No. Set" feature outlined on pg. 114 of the training manual, run the "part" program from the
point where cutting stopped.
6>
Unload the sheet using the loader in the "manual" mode.
7>
Edit the "part" sub-program:
8>
If using the "l" method:
1)
Edit the "main" pgm
"l#" for the remaining
number of sheets -1.
2)
Run the main pgm.
change the last line (M99;) to ( M30; )
change the last line back to (M99;)
If using the "repeat" method:
1) Using the "seq. No. Set" feature,
run the "main" pgm. From the
point where cutting stopped.
76

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the STX SC L PLUS CONTROL and is the answer not in the manual?

Table of Contents