Mazak STX SC L PLUS CONTROL Training Manual page 51

Table of Contents

Advertisement

1.
HAS THE FOCUS LENS BEEN CONTAMINATED BY WATER OR OIL ?
( IF THE LENS HAS BEEN EXPOSED TO WATER OR OIL FROM ANY
SOURCE, INCLUDING CLEANING AGENTS, THE COATING MAY BE
DAMAGED EVEN THOUGH IT APPEARS OK. )
2.
IS THE MATERIAL COMPOSITION AND SURFACE QUALITY ADEQUATE ?
3.
IS THE MATERIAL TEMPERATURE TOO HIGH DUE TO CUTTING IN CLOSE
PROXIMITY TO A PREVIOUSLY CUT HOLE ?
4.
ARE THE CUT CONDITIONS SUITABLE FOR THE PARTICULAR GEOMETRY ?
5.
IS THE BRASS PROFILER RING EXTREMELY WORN ?
( CAN CAUSE INCONSISTENCY IN THE PROFILER UNIT )
6.
IS THE ASSIST GAS PURITY SUFFICIENT ?
7.
IS THE LASER GAS PURITY AND MIXING RATIO WITHIN SPECIFICATIONS ?
8.
IS THE CHILLER TEMPERATURE CORRECT ? HAS THE CHILLER BEEN FLUSHED
REGULARLY ?
9.
IS THE PURGE AIR SUPPLIED TO THE EXTERNAL OPTICS CLEAN ?
( IF FUMES FROM PAINT OR SOLVENTS ARE DRAWN INTO THE AIR
COMPRESSOR THE AIR BECOMES CONTAMINATED ).
10.
IS THE AIR PRESSURE CONSTANT ON THE CHILLER REGULATOR ?
11.
IS THE SECONDARY REGULATOR FOR THE OXYGEN SET AT 115 PSI. ?
( ONLY APPLIES WHEN THE OXYGEN IS CONNECTED TO THE O2 GAS-IN PORT )
12.
WHEN WAS THE PHASE RETARDER LAST REPLACED ?